LEAP Bridge Concrete (LBC)
- Enhancements for PennDOT
- Minimum steel reinforcement requirement per PennDOT DM-4
- Custom distribution of SIP loads
- Custom flexural capacity calculations per PennDOT DM-4
- Custom legal and permit trucks to the available design trucks
- Custom setting of P/S strand debonding length
- Custom limiting stress factors
- Custom resistance factor for voided box girders
- Show the envelope of P-Delta effects in Analysis results
- Enhancement of analysis reporting of superstructure for multi-span concrete bridges
The following issues are fixed:
- Design parameter factor of Release Time of the deck was reverted to 0.75 each time when the program was closed and reopened in Precast/Prestressed Girder module.
- Minimum ratio of deck overhang to thickness was incorrectly implemented in deck design with empirical method in Precast/Prestressed Girder module.
- With the option Run Girder-by-Girder was toggled on, the results of the rating with user defined truck were missing in Precast/Prestressed Girder module.
- Incorrect header of the service limit state check report in Precast/Prestressed Girder module.
- The report did not correctly show the case in the horizontal shear design check when the option intentionally Roughened was selected in Precast/Prestressed Girder module.
- Incorrect reactions were shown for permit trucks under Strength Limit State II in Precast/Prestressed Girder module.
- Incorrect live load deflection was reported when the options of flared girders and girder-by-girder were selected for analysis in Precast/Prestressed Girder module.
- Concrete modulus of elasticity of pier cap was incorrectly reported for stem wall abutment in Substructure module.
- Width of approach slab was incorrectly not allowed to great than 100 feet in Substructure module.
- Self-weight was incorrectly calculated when stepped cap was selected for beam seat of stem wall abutment in Substructure module.
- Barrier height was incorrectly hard coded in the Superstructure Parameters window in Substructure module.
- Input of "Length of Live Load" in the auto-generation of the wind load effect was unable to be retained in Substructure module.
- Details of live loads from the multiple rounds of auto-generation were incorrect in Substructure module.
- Load effects due to uniform temperature load were incorrectly generated in stem wall abutment in Substructure module.
- Incorrect moment diagram of pier column was shown when a user defined checking point was added to pier column in Substructure module.
- Station of the end of bridge was calculated incorrectly when the option Along Girder Between Piers was selected to generate the deck elevation report.
- Callout of dimensions was abnormally small when the program was run for the first time after installation.
- Unknown error when clicked Report Selection button, leading to incompletely generated reports.