In a DWG drawing with clipped reference files. The clip boundary is
displayed and can not be selected or turned off.
This is controlled by the DWG variable xclipframe. In the key-in browser
type "DWG xclipframe 0" to turn the display of the reference clip
boundary off. Setting it to 1 to turn the display of the reference clip
boundary on.