How To Add A Column For Width In Partlists


  
 Applies To 
  
 Product(s):ProSteel 3D Professional
 Version(s):N/A
 Environment: N/A
 Area: Reports/Bill of material
 Subarea: 
 Original Author:Steffen Knoll, Bentley Technical Support Group
  

Overview

Reports done by the partlist feature can display all information saved in the mdb file. To make this information visible new columns must be added. This sample is about a new column for the width.

Steps to Resolve

  1. Open LST file in ProStructures Partlist via menu Settings/Edit partlist definition

  2. Double click table to open Table Contents - Partlist

  3. Starting with Header line, copy and insert "length"

  4.  Double click new entry and change it to "width"

  5. Do the same on tab Data Line and change the new entry to:

    Fstr$(width,"?&")



 

See Also