Background
OpenPlant Isometrics Manager places Flow arrow annotation in the NOTES cell. Some user wants to turn off the Flow arrow annotation. We can do this by turning off the User label Notes, but it would turn off all notes
Following steps helps to turn off flow arrow annotation but keep remain on other notes.
Steps to Accomplish
Open isometric configuration.
Click on isometric style tab.
Select ‘User label note’.
Add following entry
Exclude: EC_CLASS=’FLOW_ARROW’
Note: For OpenPLANT Isometric manager 08.11.09.470 and above add the entry in Variable Shape Note instead of Note lablels like below image.