Error: Scaler, Symbols or Item code are missing for TAP_CONNECTION when Branch Connected Through Stu


Applies To
Product(s):OpenPlant Isometrics Manager & AutoPlant Modeler
Version(s):08.11.09.458 & 08.11.11.135
Environment:Windows 7 (64 bit)
Area:Settings/Attributes
Subarea:
Original Author:Abhijit Bute, Bentley Product Advantage Group

Problem Description

Using AutoPLANT Modeler & OpenPlant Isometrics Manager user is getting error as "Scaler, Symbols or item codes are missing for TAP_CONNECTION" while generating isometrics as shown below.

Scaler, Symbols or Item code are missing for TAP_CONNECTION error message when branch connected through Stub-In tap port. 

Steps to Resolve

  1. Open Class Editor and go to File>Open navigate to project path.
  2. Open ‘OpenPlant_3D.01.04.ecschema.xml’ & supplement it with "OpenPlant_3D_Supplemental_Isometrics_Isoextractor.01.04.ecschema.xml" Schema.
  3. Search TAP_CONNECTION class.
  4. Change the value in “Item Code” from this.COMPONENT_NAME to “TAG”

    Note - Add the string quotes " " around TAG as "TAG".

  5. Save & close schema.
  6. Restart document manager generate isometric to verify result.

Still a Problem?

If above problem still persist, then please create a Service Request and contact the Bentley Product Advantage group.  Please include a list of all relevant details to get in depth analysis for a solution or workaround.

See Also

communities.bentley.com/.../errors-logs-messages-crashes---openplant-isometrics-manager-for-autoplant

Comments or Corrections?