How to Manage Supports Sequence in BOM List for AutoPLANT - OpenPlant Isometrics


Applies To
Product(s):OpenPlant Isometrics Manager CONNECT Edition
Version(s):10.XX.XX.XX
Environment:Windows 10 (64 bit)
Area:Settings/Attributes
Subarea:
Original Author:Abhijit Bute, Bentley Product Advantage Group

Problem Description

During isometric generation user has configured report.def to move pipe support form Shop session to Field session. However, the sequence of components in the field doesn't confirm their standard.

          

Steps to Resolve      

  1. Open Report.def file & comment Support entries with "#" sign. See image below.


  2. Go to project location and open ‘style.cfg’ file in notepad.
    See default path: C:\ProgramData\Bentley\Plant V8i\Bentley Plant V8i Projects\SAMPLE_METRIC\Config\OpenPlant\Isometrics\styles\IFC\config

  3. Edit ‘style.cfg’ as per below image.


  4. Save the file.
  5. Generate isometric by using specific style (IFC).

Still a Problem?

If above problem still persist, then please create a Service Request and contact the Bentley Product Advantage group.  Please include a list of all relevant details to get in depth analysis for a solution or workaround. 

See Also

communities.bentley.com/.../how-to-show-support-components-under-field-or-shop-material-list-in-bom

communities.bentley.com/.../how-to-set-component-to-shop-or-field-in-bom-depending-upon-the-value-in-autoplant-modeler

communities.bentley.com/.../autoplant---openplant-isometrics-manager-connect-edition

Comments or Corrections?

Bentley's Product Advantage Group requests that you please confine any comments you have on this Wiki entry to this Comments or Corrections?" section. THANK YOU!