Product(s): | OpenBuildings Energy Simulator | ||
Version(s): | CONNECT Edition | ||
Area: | Part L |
Criterion 2 of the BRUKL compliance report considers the operation of the building fabric - flagging in red any figures that exceed the allowed maximums - i.e. Ua-calc > Ua-limit.
However it is possible to have surface U-values that exceed the stated maximums, but do not flag a warning.
In cases such as this, all the U-values of windows in the room are being considered. The values for Ua-calc are calculated by the SBEM calculation engine using an area-weighted average method. Therefore, if glazing with the high U-value only accounts for a small percentage of the overall glazed area of the room(s) then it will have a minimal impact in the final result.
The glazing with the highest U-value is still shown in the Ui-calc column.