Error Code 20 - EXTERNAL PRESSURE: stiffener (No. xxx) INSUFFICIENT or NOT CONSI.... message appear


Applies To  
Product(s): AutoPIPE Vessel
Version(s): ALL
Area: Error Message
Date Logged
& Current Version
Jan 2025
45.00.03.001

Problem:

The following message appears in AutoPIPE Vessel, how to avoid it?

20        EXTERNAL PRESSURE: stiffener (No. xxx) INSUFFICIENT or NOT CONSIDERED

Solution:

As mentioned by the error text, the stiffener is insufficient. Open the complete report and select the hyperlink text to go to the report section in question.

Example:

Modify the stiffener as needed until the message is no longer shown.

See Also

Error Messages

Bentley AutoPIPE Vessel