W2261-3: Invalid Pipe ID in "Virtual Anchor" data for following Soil Id(s)...warning message appear


Applies To
Product(s):AutoPIPE
Version(s):ALL;
Area: Warning
Date Logged
& Current Version
Dec 2022
12.08.00.15

Problem:

The following is displayed when using AutoPIPE

 * * * W A R N I N G - MODEL * * *
W2261-3:  Invalid Pipe ID in "Virtual Anchor" data for following Soil Id(s)

36O30  
                                                                                             

Why and How to avoid it?

Solution:

This warning refers to the specified Soil ID mentioned by the warning (ex. 36O30), the Virtual Anchor data may have some inconsistent data. 

Avoidance

Open the referenced Soil ID Virtual Anchor dialog and confirm Pipe ID specified on the dialog to be correct.

If yes, press the keyboard Tab key and cycle through all of the fields. When OK button is highlighted press Enter key on the keyboard to close the dialog.

If No, correctly select correct Pipe ID from the drop down listing, then use the keyboard Tab key and cycle through all of the fields. When OK button is highlighted press Enter key on the keyboard. to close the dialog.

Final steps, be sure to press OK to close the Edit Soil Properties dialog, then press Apply button on the Soil Properties dialog, and then continue using the program as needed. These final steps are important to ensure that the model database was correctly updated with the settings on the various soil dialogs.   

NoteThis warning may be indicated if the model was created in an earlier version and then opened in a new version; the database needs to update to the new version and to confirm Soil settings. Again, by cycling through the Virtual Anchor dialog and pressing Apply on the Soil Properties dialog will resolve the this warning message from being displayed in the model consistency report . 

See Also

"Warnings" Messages

Bentley AutoPIPE