AutoPIPE CONNECT v.12.03.00.17 - Read Me file


What is New & Changed in AutoPIPE®


AutoPIPE CONNECT Edition version 12.3 (v12.03.00.17:2020-03)

The following outline identifies new features and enhancements in the AutoPIPE CONNECT Edition version 12.03.00.17.

  [Technology Preview ]

Technology Previews provide users preliminary access to features currently in development but not yet ready for production. These features are provided at no additional charge to promote awareness of a feature or technology to be deployed in a future release. Users are encouraged to provide feedback and suggestions. To learn more about Technology Previews, please create a Service Request (be sure to include "Technology Preview" in the Description field).


AutoPIPE®  Requirements


Product Version

ProductAutoPIPE
Versionv12.03.00.17
LanguageEnglish
Japanese (January 2021)


Included Applications Versions

PCF Translatorv1.0.0.82
Straitv6.0.0.16
BatchGenv1.0.0.4
ADL2NTLv1.0.0.22
Nozzlev8.11.8.35
OPIMv10.06.00.23
Connect Advisorv10.01.00.154
Connection Clientv10.00.17.10

Installation Requirements

CD drive or access to the Internet required for product installation. The minimum system configuration for installation:

Operating SystemMicrosoft Windows 8 Professional or higher
Microsoft Windows 8.1 Professional or higher (with KB2919355 Update)
Microsoft Windows 10 Professional or higher
32 or 64 bit OS
.NET Framework3.5 SP1
4.6.1

When installing the product through the installer program, the required components will be installed automatically. The contents of the Desktop Prerequisite Pack include:


Minimum Profile

The minimum recommended workstation profile for running AutoPIPE is:

ProcessorIntel Pentium IV or higher.
Memory1 GB recommended. More memory almost always improves performance, particularly when working with larger models.
Hard Disk1 GB free disk space (not including Restore Point space requirements).
Video Graphics CardAny industry-standard video card which supports OpenGL 3D graphics.
ProjectWiseProjectWise Server 10.00.03.235 with ProjectWise Explorer 10.00.03.235, ProjectWise Server 10.00.03.140 with ProjectWise Explorer 10.00.03.140, ProjectWise Server 10.0.1.67 with ProjectWise Explorer 10.0.1.67, ProjectWise Server 10.0.0 with ProjectWise Explorer 10.0.0.11 or higher, ProjectWise Server 8.11.7 with ProjectWise Explorer 8.11.7.133 or higher, ProjectWise Server 8.11.9 with ProjectWise Explorer 8.11.9, ProjectWise Server 8.11.11 with ProjectWise Explorer 8.11.11.
OpenPlant Isometrics ManagerCONNECT Edition Update 5 - 10.05 or higher
PDF ReaderAdobe® Acrobat Reader 7.0 or greater

Download and Installation


See the AutoPIPE Quick Start Guide (..\Documents\Quickstart_AutoPIPE.pdf) for more information on downloading and installing AutoPIPE.

To complete the licensing process, you must have the appropriate roles assigned by your Site Administrator. If you have not been assigned these roles, you will need to obtain the name of your Site Administrator by submitting a Service Request at http://apps.bentley.com/srmanager/ProductSupport.

If you are experiencing problems logging into your Bentley account, please contact bentley at 1-800-BENTLEY (1-800-236-8539). Outside the United States +1 610-458-5000.

Network Considerations - Network drives are only supported for data files.


Applications Included in the Installation Package

AutoPIPE Standard, AutoPIPE Advanced, AutoPIPE Nuclear, and add-ons are installed from one executable.

NOTE: For further information on translators, please refer to their respective readme files.


Documentation


Program Help: Detailed feature information may be accessed directly from the calling application by selecting the Help command, or by pressing the Help button from any of the application dialogs. Be sure to explore the program Help for answers to your questions. A set of supplemental How To, Tutorial, and Reference Information documents in PDF format are provided in the Supplemental Documentation folder (Bentley AutoPIPE > Supplemental Information) of the main Program Help file (autopipe.chm).

Tutorials: Documentation for AutoPIPE applications is provided online in the Adobe.pdf format. These files are accessible from the Help Menu. All documents can be browsed, searched, or printed with the Adobe Acrobat Reader. Information and how to download a FREE copy of the Adobe Acrobat Reader can be obtained from http://www.adobe.com/.

It is highly recommended that you obtain the latest version of the Adobe Acrobat Reader.


Piping Codes


Standard Edition Piping Codes

Piping CodeDescriptionEditions
B31.1 PowerPower Piping1967, 1986, 1992, 2004, 2005 Addenda, 2007, 2009 Addenda, 2010, 2012, 2014, 2016, 2018
B31.3 Process PipingProcess Piping2004, 2006, 2008, 2010, 2012, 2014, 2016, 2018
B31.4 Liquid Trans.Liquid Transportation Systems for Hydrocarbons, Liquid Petroleum Gas, Anhydrous Ammonia and Alcohols2006, 2009, 2012, 2016
B31.8 Gas Trans. & Dist.Gas Transmission and Distribution Piping Systems2003, 2007, 2010, 2012, 2014, 2016
EN 13480European Piping Code for Metallic Industrial Piping2002, 2010 Addenda, 2012, 2017
GeneralGeneral Piping CodeNot Required
ASME B31JStress Intensification Factors, Flexibility Factors, and Sustained Stress Factors used in B31 Piping Analysis2017

Extra Codes Available in AutoPIPE Advanced Edition

AutoPIPE Advanced includes all codes available in AutoPIPE Standard, as well as the following codes.

Piping CodeDescriptionEditions
CSA-Z662Canadian Standards Association, Oil and Gas Pipeline System1999, 2007, 2011, 2015
CSA-Z662 OffshoreCanadian Standards Association, Offshore Steel Pipelines1999, 2007, 2011, 2015
BS 806Design and Construction of Ferrous Piping Installations for and in Connection with Land Boilers1993
BS 7159Design and Construction of Glass Reinforced Plastics (GRP) Piping Systems for Individual Plants or Sites1989
SPC-2Swedish Piping Code, Method 21978
TBK5-6General Rules for Piping, The Norwegian Pressure Vessel Committee1990
STOOMWEZENDutch Piping Rule D1101 of the Rules for Pressure Vessels1978
DNV OffshoreDet Norske Veritas, Rules for Submarine Pipelines1981, 2012
MITI 501 3-1980MITI 501 Class III Piping Code1980
KHKKHK E 012 Piping Code, Seismic Level 1 or 2 (Seismic Level 2 requires a KHK 2 Add-On license)2006
RCC-MFrench Piping Code for Power Industry1985
SNCTFrench Piping Code for Process Industry1985
SNIP Russian 2.05.06-85 Oil & GasRussian SNIP piping code for oil and gas1997
ISO 14692Petroleum and Natural Gas Industries - Glass Reinforced Plastics (GRP) Piping2002+2005 addenda
B31.4 OffshoreOffshore Liquid Piping Systems2006, 2009, 2012, 2016
B31.8 OffshoreOffshore Gas Transmission2003, 2007, 2010, 2012, 2014, 2016

Extra Codes Available in AutoPIPE Nuclear Edition

AutoPIPE Nuclear includes all codes available in AutoPIPE Standard and AutoPIPE Advanced, as well as the following codes.

Piping CodeDescriptionEditions
ASME NB NuclearBoiler and Pressure Vessel Code, Rules for Construction of Nuclear Power Plant Components; Division 1, Subsection NC, Class 1 Components1972 W Addenda, 1975 W Addenda, 1977, 1982 W Addenda, 1983 W Addenda, 1988 Addenda, 1989, 1989 Addenda, 1993 Addenda, 1994 Addenda, 1997 Addenda, 1998, 2001, 2004, 2007, 2008 Addenda, 2010, 2011 Addenda, 2013, 2015, 2017
ASME NC NuclearBoiler and Pressure Vessel Code, Rules for Construction of Nuclear Power Plant Components; Division 1, Subsection NC, Class 2 Components1972 W Addenda, 1975 W Addenda, 1977, 1980 S Addenda, 1983 W Addenda, 1988 Addenda, 1989, 1989 Addenda, 1993 Addenda, 1994 Addenda, 1997 Addenda, 1998, 2001, 2003 Addenda, 2004, 2007, 2008 Addenda, 2010, 2011 Addenda, 2013, 2015, 2017
ASME ND NuclearBoiler and Pressure Vessel Code, Rules for Construction of Nuclear Power Plant Components; Division 1, Subsection ND, Class 3 Components1972 W Addenda, 1975 W Addenda, 1977, 1980 S Addenda, 1983 W Addenda, 1988 Addenda, 1989, 1989 Addenda, 1993 Addenda, 1994 Addenda, 1997 Addenda, 1998, 2001, 2003 Addenda, 2004, 2007, 2008 Addenda, 2010, 2011 Addenda, 2013, 2015, 2017
JSME PPC NuclearJSME S NC1: Rules on Design and Construction for Nuclear Power Plants, Class 2 Piping2005, 2008

How to Activate AutoPIPE® 


Subscription Entitlement Service is Bentley's new licensing model, providing enhanced security and optimized value for your Bentley Subscriptions. It is integrated with Bentley's Identity Management System (IMS) and the Bentley CONNECT technology platform to allow near real-time reporting of usage, improved alert messaging to users and increased administrative capabilities to license administrators in your organization. It will not only give you more options to monitor and manage usage but also provide new, advanced licensing features that will enhance digital workflows.

Activation

With Subscription Entitlement Service, all users must be registered with Bentley's Identity Management System (IMS) and sign in to the CONNECTION Client to access Bentley applications. Product activation will now occur through user sign-in to the CONNECTION Client with a valid IMS ID associated with their account. User sign-in will replace traditional activation keys, offering enhanced security as administrators will be able to control which users have access to Bentley software. License entitlements are granted and maintained through Subscription Entitlement Service's Entitlement Management Service. By signing into the CONNECTION Client users can also find their organization's projects, download software updates, receive relevant notifications, and track their usage.

Alerts

Subscription Entitlement Service features the new license alerts notifications that can be set by an organization's license administrators to let the users know when they reach a set usage threshold. These notifications will alert the users that if they continue to use the product, a term license may be issued. The user in such a situation has the choice to quit the application before a license is used or acknowledge that a term license may be generated and proceed with starting the application, based on what settings the administrator chooses.


Error History


AutoPIPE v12.3.0

The following outline identifies all major errors fixed in Release of AutoPIPE v12.3.

ASCE 7-02 (Note 2, Figure 6-4) and ASCE 7-10 (Note 2, Figure 26.8-1) requires limiting the height over distance upwind of crest (H/Lh) value to 0.5 for evaluating K1 multiplier. ASCE 7 also requires substituting 2H for Lh for evaluating K2 and K3 multipliers when H/Lh exceeds 0.5. AutoPIPE wind analysis does not incorporate the two conditions above. This results in incorrect pressure value calculations for wind load cases.

Thermal expansion values for spec material A790-S31803 are incorrectly recorded in program libraries at 300F, 800F, 950F and 1300F.

AL-6XN-B688 material is using incorrect but conservative allowable values @300F and @400F when wall thickness is less than 3/16 in. Program is using allowable values of 23.92ksi and 22.88ksi instead of 24ksi and 23.68ksi @300F and @400F respectively. This issue exists in all ASME B31.3 material libraries from B313-04.LIB to B313-16.LIB.

ASCE-7-02 (Table 6-3, Note 2) exposure category B requires limiting z value to 30ft for evaluating velocity pressure coefficient Kz, but this condition is removed from ASCE-7-10 (Table 29.3-1, Note 1). However, AutoPIPE applies this limit for ASCE-7-10 incorrectly. Which results in conservative pressure results for z value up to 30ft.

Exporting very large models to SQLite DB throws an out of memory exception.

NOTE: Please contact Bentley TSG for more details.


Bentley Copyright Notice


Trademark Notice

Bentley, the "B" logo, AutoPIPE, MicroStation, ProjectWise, SELECT, and MDL are either registered or unregistered trademarks or service marks of Bentley Systems, Incorporated, or one of its direct or indirect wholly-owned subsidiaries. Other brands and product names are trademarks of their respective owners.

Copyright Notice

© 2020, Bentley Systems, Incorporated. All Rights Reserved.

Including software, file formats, and audiovisual displays; may only be used pursuant to applicable software license agreement; contains confidential and proprietary information of Bentley Systems, Incorporated and/or third parties which is protected by copyright and trade secret law and may not be provided or otherwise made available without proper authorization.

Complete copyright information can be found in the product by choosing Help > About.

For reference, a copy of the End User License Agreement named "EULA.pdf" is included in the "AutoPIPE CONNECT v12" folder of the product installation. By default, this location is "C:\Program Files (x86)\Bentley\AutoPIPE CONNECT v12".


Corporate Headquarters

Bentley Systems, Incorporated
685 Stockton Drive
Exton, PA 19341-0678 USA
Phone: (1) 610 458-5000
FAX: (1) 610 458-1060
WWW: http://www.bentley.com/
 

International Headquarters

Bentley Systems Europe B.V.
Wegalaan 2
2132 JC Hoofddorp
THE NETHERLANDS
Phone: (31) 23 556 0560
FAX: (31) 23 556 0565
WWW: http://www.bentley.com/nl-NL/

Asia Headquarters

Bentley Engineering Software Systems
Unit 1402-06, Tower 1
China Central Place, Beijing 100022
CHINA
Phone: (86) 10 5929 7000
FAX: (86) 10 5929 7001
WWW: http://www.bentley.com/zh-CN/