- Open Project Administrator>Databse>Databases>PROJDATA>Edit tables> Nozzle.
- Uncheck protected > Ok

- Click on Table Design> Add a new field NCODE
- Close the Database
- Now, in the same node in Project Administrator. Go to AT_VIEWS>AT_PID_NOZZLE>Edit>Nozzle fields and enable NCODE

- Open P&ID and Go to Annotation Tool.
- Now, select the component to Annotate i.e. Nozzle.
- Notice NCODE has been added in the vailable fields.

- Place the annotation

Note: For AutoPLANT Modeler SS5 NCODE field is ready there so skip steps 1 to 4.