The following outline identifies new features and enhancements in the AutoPIPE CONNECT Edition version 12.01.00.09.
[Technology Preview ]
Technology Previews provide users preliminary access to features currently in development but not yet ready for production. These features are provided at no additional charge to promote awareness of a feature or technology to be deployed in a future release. Users are encouraged to provide feedback and suggestions. To learn more about Technology Previews, please create a Service Request (be sure to include "Technology Preview" in the Description field).
Product | AutoPIPE |
Version | v12.01.00.09 |
Language | English |
PCF Translator | v1.0.0.77 |
Strait | v6.0.0.15 |
BatchGen | v1.0.0.3 |
ADL2NTL | v1.0.0.21 |
Nozzle | v8.11.8.35 |
CD drive or access to the Internet required for product installation. The minimum system configuration for installation:
Operating System | Microsoft Windows 7 Professional or higher (with Service Pack 1) Microsoft Windows 8 Professional or higher Microsoft Windows 8.1 Professional or higher (with KB2919355 Update) Microsoft Windows 10 Professional or higher 32 or 64 bit OS |
.NET Framework | 3.5 SP1 4.6.1 |
When installing the product through the installer program, the required components will be installed automatically. The contents of the Desktop Prerequisite Pack include:
The minimum recommended workstation profile for running AutoPIPE is:
Processor | Intel Pentium IV or higher. |
Memory | 1 GB recommended. More memory almost always improves performance, particularly when working with larger models. |
Hard Disk | 1 GB free disk space (not including Restore Point space requirements). |
Video Graphics Card | Any industry-standard video card which supports OpenGL 3D graphics. |
ProjectWise | ProjectWise Server 10.00.03.235 with ProjectWise Explorer 10.00.03.235, ProjectWise Server 10.00.03.140 with ProjectWise Explorer 10.00.03.140, ProjectWise Server 10.0.1.67 with ProjectWise Explorer 10.0.1.67, ProjectWise Server 10.0.0 with ProjectWise Explorer 10.0.0.11 or higher, ProjectWise Server 8.11.7 with ProjectWise Explorer 8.11.7.133 or higher, ProjectWise Server 8.11.9 with ProjectWise Explorer 8.11.9, ProjectWise Server 8.11.11 with ProjectWise Explorer 8.11.11. |
OpenPlant Isometrics Manager | CONNECT Edition Update 3 - 10.03.00.19 |
PDF Reader | Adobe® Acrobat Reader 7.0 or greater |
See the AutoPIPE Quick Start Guide (..\Documents\Quickstart_AutoPIPE.pdf) for more information on downloading and installing AutoPIPE.
To complete the licensing process, you must have the appropriate roles assigned by your Site Administrator. If you have not been assigned these roles, you will need to obtain the name of your Site Administrator by submitting a Service Request at http://apps.bentley.com/srmanager/ProductSupport.
If you are experiencing problems logging into your Bentley account, please contact bentley at 1-800-BENTLEY (1-800-236-8539). Outside the United States +1 610-458-5000.
Network Considerations - Network drives are only supported for data files.
AutoPIPE Standard, AutoPIPE Advanced, AutoPIPE Nuclear, and add-ons are installed from one executable.
NOTE: For further information on translators, please refer to their respective readme files.
Program Help: Detailed feature information may be accessed directly from the calling application by selecting the Help command, or by pressing the Help button from any of the application dialogs. Be sure to explore the program Help for answers to your questions. A set of supplemental How To, Tutorial, and Reference Information documents in PDF format are provided in the Supplemental Documentation folder (Bentley AutoPIPE > Supplemental Information) of the main Program Help file (autopipe.chm).
Tutorials: Documentation for AutoPIPE applications is provided online in the Adobe.pdf format. These files are accessible from the Help Menu. All documents can be browsed, searched, or printed with the Adobe Acrobat Reader. Information and how to download a FREE copy of the Adobe Acrobat Reader can be obtained from http://www.adobe.com/.
It is highly recommended that you obtain the latest version of the Adobe Acrobat Reader.
Piping Code | Description | Editions |
B31.1 Power | Power Piping | 1967, 1986, 1992, 2004, 2005 Addenda, 2007, 2009 Addenda, 2010, 2012, 2014, 2016, 2018 |
B31.3 Process Piping | Process Piping | 2004, 2006, 2008, 2010, 2012, 2014, 2016 |
B31.4 Liquid Trans. | Liquid Transportation Systems for Hydrocarbons, Liquid Petroleum Gas, Anhydrous Ammonia and Alcohols | 2006, 2009, 2012, 2016 |
B31.8 Gas Trans. & Dist. | Gas Transmission and Distribution Piping Systems | 2003, 2007, 2010, 2012, 2014, 2016 |
EN 13480 | European Piping Code for Metallic Industrial Piping | 2002, 2010 Addenda, 2012 |
General | General Piping Code | Not Required |
ASME B31J | Stress Intensification Factors, Flexibility Factors, and Sustained Stress Factors used in B31 Piping Analysis | 2017 |
AutoPIPE Advanced includes all codes available in AutoPIPE Standard, as well as the following codes.
Piping Code | Description | Editions |
CSA-Z662 | Canadian Standards Association, Oil and Gas Pipeline System | 1999, 2007, 2011, 2015 |
CSA-Z662 Offshore | Canadian Standards Association, Offshore Steel Pipelines | 1999, 2007, 2011, 2015 |
BS 806 | Design and Construction of Ferrous Piping Installations for and in Connection with Land Boilers | 1993 |
BS 7159 | Design and Construction of Glass Reinforced Plastics (GRP) Piping Systems for Individual Plants or Sites | 1989 |
SPC-2 | Swedish Piping Code, Method 2 | 1978 |
TBK5-6 | General Rules for Piping, The Norwegian Pressure Vessel Committee | 1990 |
STOOMWEZEN | Dutch Piping Rule D1101 of the Rules for Pressure Vessels | 1978 |
DNV Offshore | Det Norske Veritas, Rules for Submarine Pipelines | 1981, 2012 |
MITI 501 3-1980 | MITI 501 Class III Piping Code | 1980 |
KHK | KHK E 012 Piping Code, Seismic Level 1 or 2 (Seismic Level 2 requires a KHK 2 Add-On license) | 2006 |
RCC-M | French Piping Code for Power Industry | 1985 |
SNCT | French Piping Code for Process Industry | 1985 |
SNIP Russian 2.05.06-85 Oil & Gas | Russian SNIP piping code for oil and gas | 1997 |
ISO 14692 | Petroleum and Natural Gas Industries - Glass Reinforced Plastics (GRP) Piping | 2002+2005 addenda |
B31.4 Offshore | Offshore Liquid Piping Systems | 2006, 2009, 2012, 2016 |
B31.8 Offshore | Offshore Gas Transmission | 2003, 2007, 2010, 2012, 2014, 2016 |
AutoPIPE Nuclear includes all codes available in AutoPIPE Standard and AutoPIPE Advanced, as well as the following codes.
Piping Code | Description | Editions |
ASME NB Nuclear | Boiler and Pressure Vessel Code, Rules for Construction of Nuclear Power Plant Components; Division 1, Subsection NC, Class 1 Components | 1972 W Addenda, 1975 W Addenda, 1977, 1982 W Addenda, 1983 W Addenda, 1988 Addenda, 1989, 1989 Addenda, 1993 Addenda, 1994 Addenda, 1997 Addenda, 1998, 2001, 2004, 2007, 2008 Addenda, 2010, 2011 Addenda, 2013, 2015, 2017 |
ASME NC Nuclear | Boiler and Pressure Vessel Code, Rules for Construction of Nuclear Power Plant Components; Division 1, Subsection NC, Class 2 Components | 1972 W Addenda, 1975 W Addenda, 1977, 1980 S Addenda, 1983 W Addenda, 1988 Addenda, 1989, 1989 Addenda, 1993 Addenda, 1994 Addenda, 1997 Addenda, 1998, 2001, 2003 Addenda, 2004, 2007, 2008 Addenda, 2010, 2011 Addenda, 2013, 2015, 2017 |
ASME ND Nuclear | Boiler and Pressure Vessel Code, Rules for Construction of Nuclear Power Plant Components; Division 1, Subsection ND, Class 3 Components | 1972 W Addenda, 1975 W Addenda, 1977, 1980 S Addenda, 1983 W Addenda, 1988 Addenda, 1989, 1989 Addenda, 1993 Addenda, 1994 Addenda, 1997 Addenda, 1998, 2001, 2003 Addenda, 2004, 2007, 2008 Addenda, 2010, 2011 Addenda, 2013, 2015, 2017 |
JSME PPC Nuclear | JSME S NC1: Rules on Design and Construction for Nuclear Power Plants, Class 2 Piping | 2005, 2008 |
CONNECT licensing is Bentley's new licensing model, providing enhanced security and optimized value for your Bentley Subscriptions. It is integrated with Bentley's Identity Management System (IMS) and the Bentley CONNECT technology platform to allow near real-time reporting of usage, improved alert messaging to users and increased administrative capabilities to license administrators in your organization. It will not only give you more options to monitor and manage usage but also provide new, advanced licensing features that will enhance digital workflows.
With CONNECT Licensing, all users must be registered with Bentley's Identity Management System (IMS) and sign in to the CONNECTION Client to access Bentley applications. Product activation will now occur through user sign-in to the CONNECTION Client with a valid IMS ID associated with their account. User sign-in will replace traditional activation keys, offering enhanced security as administrators will be able to control which users have access to Bentley software. License entitlements are granted and maintained through CONNECT Licensing's Entitlement Management Service. By signing into the CONNECTION Client users can also find their organization's projects, download software updates, receive relevant notifications, and track their usage.
CONNECT Licensing features the new license alerts notifications that can be set by an organization's license administrators to let the users know when they reach a set usage threshold. These notifications will alert the users that if they continue to use the product, a term license may be issued. The user in such a situation has the choice to quit the application before a license is used or acknowledge that a term license may be generated and proceed with starting the application, based on what settings the administrator chooses.
The following outline identifies all major errors fixed in Release of AutoPIPE v12.1.
Flanges that are inserted on a segment junction/continuation* point may incorrectly use zero values for external forces and moments for the Load Combination selected in the Flange Check module. This results in stress values that does not include the effect of external forces and moments, leading to unconservative results.
Interactive results dialog may not update to represent the correct results while navigating through interactive results e.g. result > code stress results. The avoidance is to use the batch report or result grid to review the results.
Some pipe materials are using incorrect values of allowable stress, thermal expansion , ultimate strength and/or modulus of elasticity. Using these pipe materials may result in incorrect calculated stress. The calculated stress values may be conservative than the actual stress values. The impacted materials are listed below
Allowable Stress :
- A106-A is not using correct values @800 for ASME B31.1 2016 to B31.1 2012
- A376-TP347 is not using correct values @800 for ASME B31.1 1986
Young Modulus :
- ST, AU, AU-TYPE 317 & AU-TYPE 348 are not using correct values @ -100, 200, 400, 500, 1100, 1300 for ASME B31.1 2016 to B31.1 2012
- MO is not using correct values @ 200, 300, 600, 700, 900, 1000 for ASME B31.1 2016 to B31.1 2012
- CN is not using correct values @ -100 for ASME B31.1 2016 to B31.1 2012
Thermal Expansion :
- CU is not using correct value @550 for ASME B31.1 2009 to B31.1 2005
- ST & AU-TYPE 310 are not using correct values @ All temperatures for ASME B31.1 1986
Ultimate strength:
- A335-P92 & C12200-B88 are not using correct values for ASME B31.1 2016 to B31.1 2007
- A335-P92_N+T is not using correct values for ASME B31.1 2016 to B31.1 2007
Removed data:
- AU-TYPE 304, AU-TYPE 309, AU-TYPE 310, AU-TYPE 316, AU-TYPE 321, AU-TYPE 347 data removed @1500 for ASME B31.1 2016 to B31.1 2012
- NI-CR-MO data removed above 800 for ASME B31.1 2010 to B31.1 2004
For ISO 14692 piping code, virtual soil points on components other than bends use the joint properties defined for the previous physical point. Also, virtual soil points use allowable stress equations defined for joints instead of allowable equations defined for straight run.
NOTE: Please contact Bentley TSG for more details.
Bentley, the "B" logo, AutoPIPE, MicroStation, ProjectWise, SELECT, and MDL are either registered or unregistered trademarks or service marks of Bentley Systems, Incorporated, or one of its direct or indirect wholly-owned subsidiaries. Other brands and product names are trademarks of their respective owners.
© 2019, Bentley Systems, Incorporated. All Rights Reserved.
Including software, file formats, and audiovisual displays; may only be used pursuant to applicable software license agreement; contains confidential and proprietary information of Bentley Systems, Incorporated and/or third parties which is protected by copyright and trade secret law and may not be provided or otherwise made available without proper authorization.
Complete copyright information can be found in the product by choosing Help > About.
For reference, a copy of the End User License Agreement named "EULA.pdf" is included in the "AutoPIPE CONNECT v12" folder of the product installation. By default, this location is "C:\Program Files (x86)\Bentley\AutoPIPE CONNECT v12".
Corporate HeadquartersBentley Systems, Incorporated |
International HeadquartersBentley Systems Europe B.V. |
Asia HeadquartersBentley Engineering Software Systems |