When calculating the average Sm value is this done for every individual load case to start with and then the minimum Sm for every load pair assessed?
Please see the following:
Please see the following AutoPIPE help section:
Help > Contents> Search Tab> enter "Use Avg Sm allowable" (include the quotes), press List Topics button, double click on the "Use Avg Sm allowable" from the list provided to see more information.
Otherwise, it is done differently for the Pre-Verification stress which use Ambient or the load case value.
ASME BPV-III-1-NB, AutoPIPE Nuclear Piping Code FAQ