Applies To | |
Product(s): | AutoPIPE |
Version(s): | ALL; |
Area: | Stress Isometric |
Date Logged & Current Version | Feb. 2018 11.02.00.10 |
How to remove "G" from support in a stress isometric created by AutoPIPE?
Follow the procedure:
1. Close all open AutoPIPE applications
2. Manually open the following file Style.XML file from the program folder:
AutoPIPE 10 to 11.2
C:\ProgramData\Bentley\AutoPIPE CONNECT xxx\isoextractor\projects\project01\stress\Config
3. Change "G" to "(space)"
Change to:
4. Restart AutoPIPE, and create a new Stress Isometric.
Customize AutoPIPE Stress Isometric drawings