02. Why does the results grids not show the SNiP 1997 Hoop Stress Allowable results as shown in Auto


Applies To
Product(s):AutoPIPE
Version(s):ALL
Environment: N/A
Area: Calculation
Original Author:Bentley Technical Support Group
Date Logged
& Current Version
Oct. 2015
09.06.02.06

Problem:

AutoPIPE calculates a SNiP hoop allowable of 178.39 N/mm2 in the output report, but 0.0 N/mm2 in the results grid, why?

Solution:

In result grid Hoop allowable is calculated only for "Plastic Strain" category.

The results grid only prints the hoop allowable during plastic strain hoop stress check. It will never print a value for hoop allowable for the default combination Max P.

See Also

SNIP Piping Code Calculation Issues in AutoPIPE

Bentley AutoPIPE