Applies To | |||
Product(s): | AutoPIPE | ||
Version(s): | 2004, XM, V8i | ||
Environment: | N/A | ||
Area: | |||
Subarea: | |||
Original Author: | Bentley Technical Support Group | ||
Date Logged & Current Version | Mar. 2015 09.06.01.11 | ||
Is it possible to save Pipe IDs between AutoPIPE models?
Yes and No,
One cannot save PipeID's directly to another model.
However, suggest creating a master model. In this master model create short runs of pipe that will have various different PipeID associated with them with the different pipe settings. When working in a new model, Import this master model into the current model thereby automatically creating the PipeID's to match the imported piping.
Bentley Technical Support KnowledgeBase
Bentley's Technical Support Group requests that you please submit any comments you have on this Wiki article to
the "Comments" area below. THANK YOU!