Add Horizontal PI Command Only Allows One Input


  
 Applies To 
  
 Product(s):InRoads
 Version(s):08.11.07.615
 Environment: N/A
 Area: Geometry
 Subarea: 
 Original Author:Jacquelyn Pettus, Bentley Technical Support Group
  

 

 

 

 

 

 

 

 

Question:

We’ve just installed Bentley Rail Track 08.11.07.615 and Add Horizontal PI appears now to only add a single input point before having to select the command again. Is this a variable setting that I have missed or an intentional move?

Answer:

Make sure that "Dynamic Update of Design Graphics" is toggled off in Tools > Variable Manager.