Error when computing a 2D analysis: "2D Solver Error: "ModuleRunOff - ConstructDischarges - ERR11"


Product(s):SewerGEMS, CivilStorm
Version(s):CONNECT Edition
Area:Modeling

Problem

An error message is generated when computing a 2D analysis: "2D Solver Error: "ModuleRunOff - ConstructDischarges - ERR11

Solution

This issue occurs if a 2D Boundary Point is placed outside of the grid. This could also mean that the Boundary Point is placed on a grid cell that has been voided out, such as channel or pond. Moving the Boundary Point onto the grid or to a grid cell that is not voided will resolve the issue. If the Boundary Point is placed directly on an element like a cross section, you could also apply any inflow at the Boundary Point directly to the 1D element. 

Validation for this issue will be improved in a future release of SewerGEMS and CivilStorm.

See Also

2D Modeling in SewerGEMS and CivilStorm