Error computing 2D analysis with labels containing special characters, such as Portuguese or Polish


Product(s):SewerGEMS, CivilStorm
Version(s):10.04.00.158 and later
Area:Modeling

Problem

When computing a model using the 2D Engine, error messages such as the following are generated in the User Notifications:

ReadInletsFromFile - ModuleRunOff - ERR49

2D Solver Error: "ConstructSewerGEMS - ModuleRunOff - ERR281"

2D Solver Error: "ConstructSewerGEMS - ModuleRunOff - ERR210"

Solution

This is related to characters used in the label for elements in the model. For instance, characters used in Portuguese or Polish words or special characters like a "/" character can cause issues with how the data is read or stored in report or output files. 

The development team is looking into a solution this to be included in a future release of SewerGEMS and CivilStorm. For now, please replace the special characters with others in the model, such as replacing a "/" with a "_". You may be able to use the Relabel command to help with this.