| Applies To | |
| Product(s): | AutoPIPE Vessel |
| Version(s): | ALL |
| Area: | modeling |
| Date Logged & Current Version | May 2023 43.01.01.011 |
When printing data for a material, young's modulus values printed are not same as input values. for example in SI Unit, values entered are MPa x 103 (GPa) but when we print it shows MPa only.
Material, Material Database, and Default Libraries