08. When I open the .NTL file in AutoPIPE, it truncates my pressure values, why and how to avoid?


Applies To
Product(s):AutoPIPE
Version(s):All
Area: Import
Original Author:Bentley Technical Support Group
Date Logged
& Current Version
April. 2015
09.06.01.11

Problem:

When I open the .NTL file in AutoPIPE, it truncates my pressure values from 2735 to 735 (it omits the leading number). The values appear correct in the .NTL file if I open in a text editor. If I add a space in front of 2735 in the .NTL file, the number shows correctly when imported into AutoPIPE.

Solution:

This is a known issue and was fixed in a new release of the application, PCF translator v 01.00.00.36 (CAE-TR-11101)

See Also

PCF Translator FAQ & troubleshooting

Bentley AutoPIPE