Applies To | |||
Product(s): | AutoPIPE | ||
Version(s): | CONNECT | ||
Area: | Readme | ||
Date Logged & Current Version | Sept 2017 11.01.00.23 |
The following outline identifies new features and enhancements in the AutoPIPE CONNECT Edition version 11.1.0.
Technology Previews - Provide users preliminary access to features currently in development but not yet ready for production. These features are provided at no additional charge to promote awareness of a feature or technology to be deployed in a future release. Users are encouraged to provide feedback and suggestions. Now all Technology previews are available in the application. These commands have '[Technology Preview]' displayed in the tool tip.
More detailed installation information can be found in the AutoPIPE Quick Start Guide.
Product | AutoPIPE |
Version | v.11.01.00.23 |
Language | English |
CD drive or access to the Internet required for product installation. The minimum system configuration for installation:
Operating System | Microsoft Windows 7 Professional or higher (with Service Pack 1) Microsoft Windows 8 Professional or higher Microsoft Windows 8.1 Professional or higher (with KB2919355 Update) Microsoft Windows 10 Professional or higher 32 or 64 bit OS |
.NET Framework |
3.5 SP1 |
When installing the product through the installer program, the required components will be installed automatically. The contents of the Desktop Prerequisite Pack include:
The minimum recommended workstation profile for running AutoPIPE is:
Processor | Intel Pentium IV or higher. |
Memory | 1 GB recommended. More memory almost always improves performance, particularly when working with larger models. |
Hard Disk | 1 GB free disk space (not including Restore Point space requirements). |
Video Graphics Card | Any industry-standard video card which supports OpenGL 3D graphics. |
ProjectWise |
ProjectWise Server 10.0.1.67 with ProjectWise Explorer 10.0.1.67 ProjectWise Server 10.0.0 with ProjectWise Explorer 10.0.0.11 or higher ProjectWise Server 8.11.7 with ProjectWise Explorer 8.11.7.133 or higher ProjectWise Server 8.11.9 with ProjectWise Explorer 8.11.9 ProjectWise Server 8.11.11 with ProjectWise Explorer 8.11.11. |
OpenPlant Isometrics Manager V8i |
08.11.11.277 |
PDF Reader | Adobe® Acrobat Reader 7.0 or greater |
QA Users:
Only model analysis performed on a AutoPIPE version installed from the QA CD sent by the QA manager are concerted to be certified under the QA Procedures. Any model analysis performed on a AutoPIPE version installed from a downloaded file should be considered invalid and must be re-run on a certified installation of the program.
See Link here for valid installation procedure.
Non-QA Users:
Product Download and Installation To download the products or to complete the licensing process, you must have the appropriate roles assigned by your Site Administrator. If you have not been assigned these roles, you will need to obtain the name of your Site Administrator by submitting a Service Request at http://apps.bentley.com/srmanager/ProductSupport.
If you are experiencing problems logging into your Bentley account, please contact bentley at 1-800-BENTLEY (1-800-236-8539). Outside the United States +1 610-458-5000.
With the appropriate privileges you can obtain the software as an electronic file from Web Downloads. Once you have installed the desired product you will need to complete the product authorization process by obtaining a license file from Bentley.
SELECT Services Online: The installation program will guide you through the process, prompting you for information when required.
If you are upgrading from an earlier version of the application, it is highly recommended that you do not install this product over the previous version.
NOTE: This is a standalone installation, no other previous installed product version is required.
Downloading the files from SELECT Services Online/Download - the download process gives you a choice to save the file to a specified location, or to begin the installation from the download area.
Network Considerations - Network drives are only supported for data files.
> AutoPIPE software must be installed on a local client workstation.
> AutoPIPE data files (*.DAT) must have full read/write access to be opened and edited.
See the AutoPIPE Quick Start Guide (..\Documents\Quickstart_AutoPIPE.pdf) for more information on downloading and installing AutoPIPE.
AutoPIPE Standard, AutoPIPE Advanced, AutoPIPE Nuclear, and add-ons are installed from one executable.
NOTE: For further information on translators, please refer to their respective readme files.
Program Help: Detailed feature information may be accessed directly from the calling application by selecting the Help command, or by pressing the Help button from any of the application dialogs. Be sure to explore the program Help for answers to your questions.
Tutorials: Documentation for AutoPIPE applications is provided online in the Adobe.pdf format. These files are accessible from the Help Menu. All documents can be browsed, searched, or printed with the Adobe Acrobat Reader. Information and how to download a FREE copy of the Adobe Acrobat Reader can be obtained from http://www.adobe.com/.
It is highly recommended that you obtain the latest version of the Adobe Acrobat Reader.
If you do not have access to the World Wide Web, please contact us so we can provide you with the necessary files for using the Adobe Acrobat Reader.
This sections contains the list of piping codes, code editions supported and AutoPIPE license edition (Standard, Advanced or Nuclear) for which these items are supported.
Piping Code | Description | Editions |
B31.1 Power | Power Piping | 1967, 1986, 1992, 2004, 2005 Addenda, 2007, 2009 Addenda, 2010, 2012, 2014, 2016 |
B31.3 Process Piping | Process Piping | 2004, 2006, 2008, 2010, 2012, 2014, 2016 |
B31.4 Liquid Trans. | Liquid Transportation Systems for Hydrocarbons, Liquid Petroleum Gas, Anhydrous Ammonia and Alcohols | 2006, 2009, 2012, 2016 |
B31.8 Gas Trans. & Dist. | Gas Transmission and Distribution Piping Systems | 2003, 2007, 2010, 2012, 2014, 2016 |
EN 13480 | European Piping Code for Metallic Industrial Piping | 2002, 2010 Addenda, 2012 |
General | General Piping Code | Not Required |
ASME B31J |
Stress intensification factors, flexibility factors, and sustained stress factors used in B31 piping analysis | 2017 |
AutoPIPE Advanced includes all codes available in AutoPIPE Standard, as well as the following codes.
Piping Code | Description | Editions |
CSA-Z662 | Canadian Standards Association, Oil and Gas Pipeline System | 1999, 2007, 2011, 2015 |
CSA-Z662 Offshore | Canadian Standards Association, Offshore Steel Pipelines | 1999, 2007, 2011, 2015 |
BS 806 | Design and Construction of Ferrous Piping Installations for and in Connection with Land Boilers | 1993 |
BS 7159 | Design and Construction of Glass Reinforced Plastics (GRP) Piping Systems for Individual Plants or Sites | 1989 |
SPC-2 | Swedish Piping Code, Method 2 | 1978 |
TBK5-6 | General Rules for Piping, The Norwegian Pressure Vessel Committee | 1990 |
STOOMWEZEN | Dutch Piping Rule D1101 of the Rules for Pressure Vessels | 1978 |
DNV Offshore | Det Norske Veritas, Rules for Submarine Pipelines | 1981, 2012 |
MITI 501 3-1980 | MITI 501 Class III Piping Code | 1980 |
KHK | KHK E 012 Piping Code, Seismic Level 1 or 2 (Seismic Level 2 requires a KHK 2 Add-On license) | 2006 |
RCC-M | French Piping Code for Power Industry | 1985 |
SNCT | French Piping Code for Process Industry | 1985 |
SNIP Russian 2.05.06-85 Oil & Gas | Russian SNIP piping code for oil and gas | 1997 |
ISO 14692 | Petroleum and Natural Gas Industries - Glass Reinforced Plastics (GRP) Piping | 2002+2005 addenda |
B31.4 Offshore | Offshore Liquid Piping Systems | 2006, 2009, 2012, 2016 |
B31.8 Offshore | Offshore Gas Transmission | 2003, 2007, 2010, 2012, 2014, 2016 |
AutoPIPE Nuclear includes all codes available in AutoPIPE Standard and AutoPIPE Advanced, as well as the following codes.
Piping Code | Description | Editions |
ASME NB Nuclear | Boiler and Pressure Vessel Code, Rules for Construction of Nuclear Power Plant Components; Division 1, Subsection NC, Class 1 Components | 1972 W Addenda, 1975 W Addenda, 1977, 1982 W Addenda, 1983 W Addenda, 1988 Addenda, 1989, 1989 Addenda, 1993 Addenda, 1994 Addenda, 1997 Addenda, 1998, 2001, 2004, 2007, 2008 Addenda, 2010, 2011 Addenda, 2013, 2015 |
ASME NC Nuclear | Boiler and Pressure Vessel Code, Rules for Construction of Nuclear Power Plant Components; Division 1, Subsection NC, Class 2 Components | 1972 W Addenda, 1975 W Addenda, 1977, 1980 S Addenda, 1983 W Addenda, 1988 Addenda, 1989, 1989 Addenda, 1993 Addenda, 1994 Addenda, 1997 Addenda, 1998, 2001, 2003 Addenda, 2004, 2007, 2008 Addenda, 2010, 2011 Addenda, 2013, 2015 |
ASME ND Nuclear | Boiler and Pressure Vessel Code, Rules for Construction of Nuclear Power Plant Components; Division 1, Subsection ND, Class 3 Components | 1972 W Addenda, 1975 W Addenda, 1977, 1980 S Addenda, 1983 W Addenda, 1988 Addenda, 1989, 1989 Addenda, 1993 Addenda, 1994 Addenda, 1997 Addenda, 1998, 2001, 2003 Addenda, 2004, 2007, 2008 Addenda, 2010, 2011 Addenda, 2013, 2015 |
JSME PPC Nuclear | JSME S NC1: Rules on Design and Construction for Nuclear Power Plants, Class 2 Piping | 2005, 2008 |
AutoPIPE Standard, AutoPIPE Advanced, AutoPIPE Nuclear, and add-ons are are all supported on the SELECT Server Licensing. If you are upgrading from an earlier version of the product, it is highly recommended that you do not install this product over the previous version. Older versions of AutoPIPE 6.3, 8.50, 8.51 and 8.60 will run under SELECT Server XM Licensing using the SELECT Server XM Gateway Service and the older SELECT licenses. For more information on the SELECT Server XM Gateway Service see the AutoPIPE Quick Start Guide.
The AutoPIPE products can be authorized as Standalone Licenses (formerly called Fixed Licenses), fixed to one user workstation or as Concurrent Licenses (formerly known as Floating Licenses) running from a local or Bentley hosted SELECT Server.
Users who have existing Floating Licenses and wish to convert the licenses to run on SELECT Server can contact Bentley Sales Support Center from the website at http://www.bentley.com/en-US/Services/Bentley+Sales+Support.htm. The following information is required when requesting SELECT Server licensing: Server Name, email address of the recipient of the SELECT Server license and the Serial Numbers to be added to the server.
Product activation is achieved by connecting to a SELECT Server, receiving a verification that your SELECT Server Name and Activation Key are correct, and successfully posting Usage logs. Product activation is not the same as checking out a license. This document describes how to configure AutoPIPE for activation. After initial configuration, AutoPIPE automatically and transparently tries to activate each time it runs, and runs unconstrained for a period of 30 days after its last successful activation. However, if activation is unsuccessful for a period of 30 days, AutoPIPE will not start until it is activated again.
The Product Activation Wizard is designed to step users through the product activation process. After a product is installed, you must obtain a license and then activate that license. Obtaining the license alone is not enough to complete the process. This wizard eliminates the confusion and makes it clear that obtaining a license and activating a product are two essential steps.
The Product Activation Wizard opens automatically (unless the "Activate product using Bentley License Tool" check box is turned off) at the end of the product installation process. See the AutoPIPE Quick Start Guide for more information on installing AutoPIPE.
The first screen of the Product Activation Wizard offers four product activation options:
SELECT subscribers with a deployed (local) SELECT Server
SELECT subscribers activating against a hosted (Bentley) SELECT Server
Non-SELECT users
Evaluation Only - No license information
The wizard steps you through the activation process based on the options selected.
If you are activating against a local SELECT Server, you must provide the proper Server Name and Activation Key. The Server Name and Activation Key, along with any proxy configuration information, can be obtained from your Site Administrator.
If you are activating against a hosted (Bentley) SELECT Server, the Server Name is pre-populated but you must provide the proper Activation Key provided by the Bentley Sales Support Center.
If you are not a Bentley SELECT subscriber and you are activating AutoPIPE, you are presented with three options:
The following outline identifies all major errors in this release:
ASME NB: Tee moments may use incorrect sign and may lead to incorrect stress results when combining signed and unsigned combinations
ASME NB: Changing fatigue curve for a pipe identifier may modify fatigue curves for other pipe identifier(s). Due to this incorrect modification, the reported Usage factor values may be lower than expected values, leading to unconservative results
ASME NB: Stress, allowable and SIF calculations for a reducer may use incorrect Pipe properties and Pressure/Temperature data. Using these incorrect values may results in lower eq. 11 stresses, higher ratchet allowable, higher eq. 10 allowable, and lower B2 stress index
ASME NC/ND: Stress Summary calculations incorrectly uses branch pressure and geometry for pressure term calculations of "P + WGT + Rev. Dyn" stresses at a tee point.
ASME Nuclear: Incorrect density, composition, and modulus values for standard pipe materials NI and GROUP-1-B
Multiple Supports Response Spectrum analysis does not produce results when SAM displacement is applied to anchors connected to beam members
On duplicating a wind load, changing the wind direction of one case also updates the direction of duplicated case.
Hydrotest for beams is multiplying thermal anchor movements with temperature factor and incorrectly adding them to thermal anchor movements for displacement calculations
TRADEMARK NOTICE
Bentley, the "B" logo, AutoPIPE, MicroStation, ProjectWise, SELECT, and MDL are either registered or unregistered trademarks or service marks of Bentley Systems, Incorporated, or one of its direct or indirect wholly-owned subsidiaries. Other brands and product names are trademarks of their respective owners.
COPYRIGHT NOTICE
© 2015, Bentley Systems, Incorporated. All Rights Reserved.
Including software, file formats, and audiovisual displays; may only be used pursuant to applicable software license agreement; contains confidential and proprietary information of Bentley Systems, Incorporated and/or third parties which is protected by copyright and trade secret law and may not be provided or otherwise made available without proper authorization.
Complete copyright information can be found in the product by choosing Help > About.
For reference, a copy of the End User License Agreement named "EULA.pdf" is included in the "AutoPIPE V8i SELECTseries5" folder of the product installation. By default, this location is "C:\Bentley\AutoPIPE V8i SELECTseries5".
Corporate HeadquartersBentley Systems, Incorporated |
International HeadquartersBentley Systems Europe B.V. |
Asia HeadquartersBentley Engineering Software Systems |
AutoPIPE CONNECT Release Notes (10.00.xx.xx - higher)
How do I download, install, and license AutoPIPE?
AutoPIPE CONNECT QA Release Notes (11.01.00.017)