Inlets are Randomly Displayed


  
 Applies To 
  
 Product(s):InRoads
 Version(s):08.11.07.615
 Environment: N/A
 Area: Drainage
 Subarea: 
 Original Author:Sanders Thomas, Bentley Technical Support Group
  

 

 

 

 

 

 

 

 

Question:

I have inlets Left/Right of the centerline at the same station and they not displayed at all locations within my drainage profile.

 

Solution:

This behavior normally occurs when Branch lines are not displayed; to do so, select Create Profile>Network>Branch Line.