QUESTION: How does the program applies multiple presence factor ?

ANSWER:

Regarding the Multiple presence factor , if the user is inputting the LL reactions manually then he has to multiply the MPF with the LL reactions and then input the values in RC pier .When the user generates the Live load reaction then the program multiplies the LL reactions with the MPF in the LOADS TAB itself.