MAXSURF | MOSES | SACS Forum - SACS v16 Pile Unity Check No UC Value
BMPCreated with Sketch.BMPZIPCreated with Sketch.ZIPXLSCreated with Sketch.XLSTXTCreated with Sketch.TXTPPTCreated with Sketch.PPTPNGCreated with Sketch.PNGPDFCreated with Sketch.PDFJPGCreated with Sketch.JPGGIFCreated with Sketch.GIFDOCCreated with Sketch.DOC Error Created with Sketch.
Question

SACS v16 Pile Unity Check No UC Value

by
Bentley Communities Legacy Member
Expert
Created (Edited ) in MAXSURF | MOSES | SACS Forum

I have performed a run using SACS 16.0 and found something weird on pile unity check, which has shown no pile UC value in output listing file.

Is it a bug in this latest version? FYI, the input file is running based on ISO 2020 code. Running the file on older code (ISO 2007) have no issue.

image


2 Replies ( Latest reply by
)

There is no mention of ISO 19902:2020 code check option in the PSI manual in the SACS 16.0 version. 

There is a bug with PSI for ISO 19902:2020 code check. The developer is looking at this issue and fix in future release.